Essex County Soil Survey Report - Northern Part - Non-technical Map Unit Descriptions

  Map Unit:  702C  -  UDIPSAMMENTS, 3 TO 15 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            The map unit is in capability subclass 8S which has very severe limitations that make them unsuited to cultivation and that restrict their

            use to grazing.

      Text Kind/Category:  Nontechnical description/SOI

            UDIPSAMMENTS require an on-site investigation to determine suitability or limitation for intended uses.

      Text Kind/Category:  Nontechnical description/URB

            This map unit has severe limitation for use as a septic tank absorbtion field because of poor filtration. There is slight limitation for local

            roads and streets. For dwellings with basement there is slight limitation. and for small commercial buildings, there is slight limitation.

  Map Unit:  709B  -  BUXTON-ROCK OUTCROP COMPLEX, 3 TO 8 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            The BUXTON component is in capability subclass 2E indicating limitations that reduce the choice of plants or require moderate

            conservation practices. Erosion is a limitation unless close growing plant cover is maintained.

      Text Kind/Category:  Nontechnical description/AGR

            ROCK OUTCROP An on-site investigation is necessary to determine suitability and limitations.

      Text Kind/Category:  Nontechnical description/SOI

            ROCK OUTCROP can consist of up to 90 percent exposed bedrock. Most outcrops are too hard to be broken and mixed by tillage.

      Text Kind/Category:  Nontechnical description/SOI

            The BUXTON component is moderately well drained; water is removed somewhat slowly during some periods. Agronomic capability

            class is 2E. Depth to bedrock is greater than 60 inches. A seasonal high water table is normally between 1.0 and 3.0 feet below the

            surface from NOV through APR.

      Text Kind/Category:  Nontechnical description/URB

            BUXTON has severe limitation for use as a septic tank absorbtion field because of wetness and slow percolation. There is severe

            limitation for local roads and streets due to low strength and frost action. For dwellings with basement, there is severe limitation because

             of wetness and for small commercial buildings, there is severe limitation due to wetness.

  Map Unit:  709C  -  BUXTON-ROCK OUTCROP COMPLEX, 8 TO 15 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            The BUXTON component is in capability subclass 3E indicating severe limitations that reduce the choice of plants or require special

            conservation practices, or both. Erosion is a limitation unless close growing plant cover is maintained.

      Text Kind/Category:  Nontechnical description/AGR

            ROCK OUTCROP An on-site investigation is necessary to determine suitability and limitations.

      Text Kind/Category:  Nontechnical description/SOI

            ROCK OUTCROP can consist of up to 90 percent exposed bedrock. Most outcrops are too hard to be broken and mixed by tillage.

      Text Kind/Category:  Nontechnical description/SOI

            The BUXTON component is moderately well drained; water is removed somewhat slowly during some periods. Agronomic capability

            class is 3E. Depth to bedrock is greater than 60 inches. A seasonal high water table is normally between 1.0 and 3.0 feet below the

            surface from NOV through APR.

      Text Kind/Category:  Nontechnical description/URB

            BUXTON has severe limitation for use as a septic tank absorbtion field because of wetness and slow percolation. There is severe

            limitation for local roads and streets due to low strength and frost action. For dwellings with basement, there is severe limitation because

             of wetness and for small commercial buildings, there is severe limitation due to wetness and slope.

  Map Unit:  710E  -  CANTON AND CHARLTON FINE SANDY LOAMS, STEEP, EXTREMELY STONY

      Text Kind/Category:  Nontechnical description/AGR

            The CANTON component is in capability subclass 7S which has very severe limitations that make the soil unsuited to cultivation and

            that restricts its use to grazing. Stoniness is a significant limitation.

      Text Kind/Category:  Nontechnical description/AGR

            The CHARLTON component is in capability subclass 7S which has very severe limitations that make the soil unsuited to cultivation and

            that restricts its use to grazing. Stoniness is a significant limitation.

      Text Kind/Category:  Nontechnical description/SOI

            The CANTON component is well drained; water is removed readily, but not rapidly. Surface stones limit cultivation or use of equipment.

            Agronomic capability class is 7S. Depth to bedrock is greater than 60 inches. The water table is normally more than 6.0 feet below the

      Text Kind/Category:  Nontechnical description/SOI

            The CHARLTON component is well drained; water is removed readily, but not rapidly. Surface stones limit cultivation or use of

            equipment. Agronomic capability class is 7S. Depth to bedrock is greater than 60 inches. The water table is normally more than 6.0 feet

      Text Kind/Category:  Nontechnical description/URB

            CANTON has severe limitation for use as a septic tank absorbtion field because of slope and poor filtration. There is severe limitation

            for local roads and streets due to slope. For dwellings with basement, there is severe limitation because of slope and for small

            commercial buildings, there is severe limitation due to slope.

      Text Kind/Category:  Nontechnical description/URB

            CHARLTON has severe limitation for use as a septic tank absorbtion field because of slope. There is severe limitation for local roads

            and streets due to slope. For dwellings with basement, there is severe limitation because of slope and for small commercial buildings,

            there is severe limitation due to slope.

  Map Unit:  711B  -  CHARLTON-ROCK OUTCROP-HOLLIS COMPLEX, 3 TO 8 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            The HOLLIS component is in capability subclass 3E indicating severe limitations that reduce the choice of plants or require special

            conservation practices, or both. Erosion is a limitation unless close growing plant cover is maintained.

      Text Kind/Category:  Nontechnical description/AGR

            The CHARLTON component is in capability subclass 6S indicating severe limitations that make the soil generally unsuited to cultivation

            and limit its use largely to pasture.

        Text Kind/Category:  Nontechnical description/AGR

            ROCK OUTCROP An on-site investigation is necessary to determine suitability and limitations.

      Text Kind/Category:  Nontechnical description/SOI

            The CHARLTON component is well drained; water is removed readily, but not rapidly. Agronomic capability class is 6S. Depth to

            bedrock is greater than 60 inches. The water table is normally more than 6.0 feet below the surface.

      Text Kind/Category:  Nontechnical description/SOI

            The HOLLIS component is well drained; water is removed readily, but not rapidly. Agronomic capability class is 3E. Depth to bedrock is

            between 10 and 20 inches. The water table is normally more than 6.0 feet below the surface.

      Text Kind/Category:  Nontechnical description/SOI

            ROCK OUTCROP can consist of up to 90 percent exposed bedrock. Most outcrops are too hard to be broken and mixed by tillage.

      Text Kind/Category:  Nontechnical description/URB

            HOLLIS has severe limitation for use as a septic tank absorbtion field because of shallow depth to bedrock. There is severe limitation

            for local roads and streets due to shallow depth to bedrock. For dwellings with basement, there is severe limitation because of shallow

            depth to bedrock and for small commercial buildings, there is severe limitation due to shallow depth to bedrock.

      Text Kind/Category:  Nontechnical description/URB

            CHARLTON has slight limitation for use as a septic tank absorbtion field. There is slight limitation for local roads and streets. For

            dwellings with basement there is slight limitation. and for small commercial buildings, there is moderate limitation due to slope.

  Map Unit:  711C  -  CHARLTON-ROCK OUTCROP-HOLLIS COMPLEX, 8 TO 15 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            The CHARLTON component is in capability subclass 6S indicating severe limitations that make the soil generally unsuited to cultivation

            and limit its use largely to pasture.

      Text Kind/Category:  Nontechnical description/AGR

            ROCK OUTCROP An on-site investigation is necessary to determine suitability and limitations.

      Text Kind/Category:  Nontechnical description/AGR

            The HOLLIS component is in capability subclass 4E indicating very severe limitations that reduce the choice of plants or require very

            careful management, or both. Erosion is a limitation unless close growing plant cover is maintained.

      Text Kind/Category:  Nontechnical description/SOI

            The HOLLIS component is well drained; water is removed readily, but not rapidly. Agronomic capability class is 4E. Depth to bedrock is

            between 10 and 20 inches. The water table is normally more than 6.0 feet below the surface.

      Text Kind/Category:  Nontechnical description/SOI

            ROCK OUTCROP can consist of up to 90 percent exposed bedrock. Most outcrops are too hard to be broken and mixed by tillage.

      Text Kind/Category:  Nontechnical description/SOI

            The CHARLTON component is well drained; water is removed readily, but not rapidly. Agronomic capability class is 6S. Depth to

            bedrock is greater than 60 inches. The water table is normally more than 6.0 feet below the surface.

      Text Kind/Category:  Nontechnical description/URB

            HOLLIS has severe limitation for use as a septic tank absorbtion field because of shallow depth to bedrock. There is severe limitation

            for local roads and streets due to shallow depth to bedrock. For dwellings with basement, there is severe limitation because of shallow

            depth to bedrock and for small commercial buildings, there is severe limitation due to slope and shallow depth to bedrock.

      Text Kind/Category:  Nontechnical description/URB

            CHARLTON has moderate limitation for use as a septic tank absorbtion field because of slope. There is moderate limitation for local

            roads and streets due to slope. For dwellings with basement, there is moderate limitation because of slope and for small commercial

            buildings, there is severe limitation due to slope.

  Map Unit:  711D  -  CHARLTON-ROCK OUTCROP-HOLLIS COMPLEX, 15 TO 25 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            The CHARLTON component is in capability subclass 6S indicating severe limitations that make the soil generally unsuited to cultivation

            and limit its use largely to pasture.

      Text Kind/Category:  Nontechnical description/AGR

            ROCK OUTCROP An on-site investigation is necessary to determine suitability and limitations.

      Text Kind/Category:  Nontechnical description/AGR

            The HOLLIS component is in capability subclass 6E indicating severe limitations that make the soil generally unsuited to cultivation and

            limit its use largely to pasture. Erosion is the main limitation.

      Text Kind/Category:  Nontechnical description/SOI

            The CHARLTON component is well drained; water is removed readily, but not rapidly. Agronomic capability class is 6S. Depth to

            bedrock is greater than 60 inches. The water table is normally more than 6.0 feet below the surface.

      Text Kind/Category:  Nontechnical description/SOI

            ROCK OUTCROP can consist of up to 90 percent exposed bedrock. Most outcrops are too hard to be broken and mixed by tillage.

      Text Kind/Category:  Nontechnical description/SOI

            The HOLLIS component is well drained; water is removed readily, but not rapidly. Agronomic capability class is 6E. Depth to bedrock is

            between 10 and 20 inches. The water table is normally more than 6.0 feet below the surface.

      Text Kind/Category:  Nontechnical description/URB

            HOLLIS has severe limitation for use as a septic tank absorbtion field because of shallow depth to bedrock and slope. There is severe

            limitation for local roads and streets due to shallow depth to bedrock and slope. For dwellings with basement, there is severe limitation

            because of shallow depth to bedrock and slope and for small commercial buildings, there is severe limitation due to slope and shallow

            depth to bedrock.

      Text Kind/Category:  Nontechnical description/URB

            CHARLTON has severe limitation for use as a septic tank absorbtion field because of slope. There is severe limitation for local roads

            and streets due to slope. For dwellings with basement, there is severe limitation because of slope and for small commercial buildings,

            there is severe limitation due to slope.

  Map Unit:  712A  -  IPSWICH AND WESTBROOK MUCKS, 0 TO 1 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            The WESTBROOK component is in capability subclass 8W which has very severe limitations that make them unsuited to cultivation and

            that restrict their use to grazing. Water in or on the soil interferes with plant growth or cultivation.

      Text Kind/Category:  Nontechnical description/AGR

            The IPSWICH component is in capability subclass 8W which has very severe limitations that make them unsuited to cultivation and that

            restrict their use to grazing. Water in or on the soil interferes with plant growth or cultivation.

      Text Kind/Category:  Nontechnical description/SOI

            The WESTBROOK component is very poorly drained; water is removed from the soil so slowly that free water remains near the surface.

            Agronomic capability class is 8W. Depth to bedrock is greater than 60 inches.

      Text Kind/Category:  Nontechnical description/SOI

            The IPSWICH component is very poorly drained; water is removed from the soil so slowly that free water remains near the surface.

            Agronomic capability class is 8W. Depth to bedrock is greater than 60 inches.

      Text Kind/Category:  Nontechnical description/URB

            WESTBROOK has severe limitation for use as a septic tank absorbtion field because of flooding and ponding. There is severe limitation

             for local roads and streets due to ponding and flooding. For dwellings with basement, there is severe limitation because of flooding and

            ponding and for small commercial buildings, there is severe limitation due to flooding, ponding and low strength.

      Text Kind/Category:  Nontechnical description/URB

            IPSWICH has severe limitation for use as a septic tank absorbtion field because of flooding and ponding. There is severe limitation for

            local roads and streets due to low strength, ponding and flooding. For dwellings with basement, there is severe limitation because of

            flooding, ponding and low strength and for small commercial buildings, there is severe limitation due to flooding, ponding and low

  Map Unit:  713A  -  LIMERICK AND RUMNEY SOILS, 0 TO 3 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            The RUMNEY component is in capability subclass 3W indicating severe limitations that reduce the choice of plants or require special

            conservation practices, or both. Water in or on the soil may interfere with plant growth or cultivation.

      Text Kind/Category:  Nontechnical description/AGR

            The LIMERICK component is in capability subclass 3W indicating severe limitations that reduce the choice of plants or require special

            conservation practices, or both. Water in or on the soil may interfere with plant growth or cultivation.

      Text Kind/Category:  Nontechnical description/SOI

            The RUMNEY component is poorly drained; water is removed so slowly that the soil is saturated or remains wet for long periods.

            Agronomic capability class is 3W. Depth to bedrock is greater than 60 inches. A seasonal high water table is normally between 0 and

            1.5 feet below the surface from NOV through MAY.

      Text Kind/Category:  Nontechnical description/SOI

            The LIMERICK component is poorly drained; water is removed so slowly that the soil is saturated or remains wet for long periods.

            Agronomic capability class is 3W. Depth to bedrock is greater than 60 inches. A seasonal high water table is normally between 0 and

            1.5 feet below the surface from NOV through MAY.

      Text Kind/Category:  Nontechnical description/URB

            LIMERICK has severe limitation for use as a septic tank absorbtion field because of flooding and wetness. There is severe limitation for

            local roads and streets due to wetness, flooding and frost action. For dwellings with basement, there is severe limitation because of

            flooding and wetness and for small commercial buildings, there is severe limitation due to flooding and wetness.

      Text Kind/Category:  Nontechnical description/URB

            RUMNEY has severe limitation for use as a septic tank absorbtion field because of flooding, wetness and poor filtration. There is severe

            limitation for local roads and streets due to flooding, wetness and frost action. For dwellings with basement, there is severe limitation

            because of flooding and wetness and for small commercial buildings, there is severe limitation due to flooding and wetness.

  Map Unit:  714B  -  MELROSE FINE SANDY LOAM, 3 TO 8 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            The map unit is in capability subclass 2E indicating limitations that reduce the choice of plants or require moderate conservation

            practices. Erosion is a limitation unless close growing plant cover is maintained.

      Text Kind/Category:  Nontechnical description/SOI

            The map unit is well drained; water is removed readily, but not rapidly. Agronomic capability class is 2E. Depth to bedrock is greater than

             60 inches. The water table is normally more than 6.0 feet below the surface.

      Text Kind/Category:  Nontechnical description/URB

            This map unit has severe limitation for use as a septic tank absorbtion field because of slow percolation. There is severe limitation for

            local roads and streets due to low strength. For dwellings with basement, there is moderate limitation because of shrink-swell and for

            small commercial buildings, there is moderate limitation due to shrink-swell and slope.

  Map Unit:  715A  -  RIDGEBURY AND LEICESTER FINE SANDY LOAMS, 0 TO 3 PERCENT SLOPES, EXTREMELY STONY

      Text Kind/Category:  Nontechnical description/AGR

            The RIDGEBURY component is in capability subclass 7S which has very severe limitations that make the soil unsuited to cultivation and

            that restricts its use to grazing. Stoniness is a significant limitation.

      Text Kind/Category:  Nontechnical description/AGR

            The LEICESTER component is in capability subclass 7S which has very severe limitations that make the soil unsuited to cultivation and

            that restricts its use to grazing. Stoniness is a significant limitation.

      Text Kind/Category:  Nontechnical description/SOI

            The RIDGEBURY component is poorly drained; water is removed so slowly that the soil is saturated or remains wet for long periods.

            Surface stones limit cultivation or use of equipment. Agronomic capability class is 7S. Depth to bedrock is greater than 60 inches. A firm

             layer at about 18 inches impedes the vertical movement of water. A seasonal high water table is normally between 0 and 0.5 feet below

            the surface from NOV through MAY.

      Text Kind/Category:  Nontechnical description/SOI

            The LEICESTER component is poorly drained; water is removed so slowly that the soil is saturated or remains wet for long periods.

            Surface stones limit cultivation or use of equipment. Agronomic capability class is 7S. Depth to bedrock is greater than 60 inches. A

            seasonal high water table is normally between 0 and 1.5 feet below the surface from NOV through MAY.

      Text Kind/Category:  Nontechnical description/URB

            LEICESTER has severe limitation for use as a septic tank absorbtion field because of wetness. There is severe limitation for local roads

             and streets due to wetness and frost action. For dwellings with basement, there is severe limitation because of wetness and for small

            commercial buildings, there is severe limitation due to wetness.

      Text Kind/Category:  Nontechnical description/URB

            RIDGEBURY has severe limitation for use as a septic tank absorbtion field because of slow percolation and wetness. There is severe

            limitation for local roads and streets due to wetness and frost action. For dwellings with basement, there is severe limitation because of

            wetness and for small commercial buildings, there is severe limitation due to wetness.

  Map Unit:  715B  -  RIDGEBURY AND LEICESTER FINE SANDY LOAMS, 3 TO 8 PERCENT SLOPES, EXTREMELY

                  STONY

      Text Kind/Category:  Nontechnical description/AGR

            The RIDGEBURY component is in capability subclass 7S which has very severe limitations that make the soil unsuited to cultivation and

            that restricts its use to grazing. Stoniness is a significant limitation.

      Text Kind/Category:  Nontechnical description/AGR

            The LEICESTER component is in capability subclass 7S which has very severe limitations that make the soil unsuited to cultivation and

            that restricts its use to grazing. Stoniness is a significant limitation.

      Text Kind/Category:  Nontechnical description/SOI

            The LEICESTER component is poorly drained; water is removed so slowly that the soil is saturated or remains wet for long periods.

            Surface stones limit cultivation or use of equipment. Agronomic capability class is 7S. Depth to bedrock is greater than 60 inches. A

            seasonal high water table is normally between 0 and 1.5 feet below the surface from NOV through MAY.

      Text Kind/Category:  Nontechnical description/SOI

            The RIDGEBURY component is poorly drained; water is removed so slowly that the soil is saturated or remains wet for long periods.

            Surface stones limit cultivation or use of equipment. Agronomic capability class is 7S. Depth to bedrock is greater than 60 inches. A firm

             layer at about 18 inches impedes the vertical movement of water. A seasonal high water table is normally between 0 and 0.5 feet below

            the surface from NOV through MAY.

      Text Kind/Category:  Nontechnical description/URB

            LEICESTER has severe limitation for use as a septic tank absorbtion field because of wetness. There is severe limitation for local roads

             and streets due to wetness and frost action. For dwellings with basement, there is severe limitation because of wetness and for small

            commercial buildings, there is severe limitation due to wetness.

      Text Kind/Category:  Nontechnical description/URB

            RIDGEBURY has severe limitation for use as a septic tank absorbtion field because of slow percolation and wetness. There is severe

            limitation for local roads and streets due to wetness and frost action. For dwellings with basement, there is severe limitation because of

            wetness and for small commercial buildings, there is severe limitation due to wetness.

  Map Unit:  716C  -  ROCK OUTCROP-BUXTON COMPLEX, 3 TO 15 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            ROCK OUTCROP An on-site investigation is necessary to determine suitability and limitations.

      Text Kind/Category:  Nontechnical description/AGR

            The BUXTON component is in capability subclass 3E indicating severe limitations that reduce the choice of plants or require special

            conservation practices, or both. Erosion is a limitation unless close growing plant cover is maintained.

      Text Kind/Category:  Nontechnical description/SOI

            The BUXTON component is moderately well drained; water is removed somewhat slowly during some periods. Agronomic capability

            class is 3E. Depth to bedrock is greater than 60 inches. A seasonal high water table is normally between 1.5 and 3.0 feet below the

            surface from NOV through MAY.

      Text Kind/Category:  Nontechnical description/SOI

            ROCK OUTCROP can consist of up to 90 percent exposed bedrock. Most outcrops are too hard to be broken and mixed by tillage.

      Text Kind/Category:  Nontechnical description/URB

            BUXTON has severe limitation for use as a septic tank absorbtion field because of wetness and slow percolation. There is severe

            limitation for local roads and streets due to low strength and frost action. For dwellings with basement, there is severe limitation because

             of wetness and for small commercial buildings, there is severe limitation due to slope.

  Map Unit:  716D  -  ROCK OUTCROP-BUXTON COMPLEX, 15 TO 25 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            The BUXTON component is in capability subclass 4E indicating very severe limitations that reduce the choice of plants or require very

            careful management, or both. Erosion is a limitation unless close growing plant cover is maintained.

      Text Kind/Category:  Nontechnical description/AGR

            ROCK OUTCROP An on-site investigation is necessary to determine suitability and limitations.

      Text Kind/Category:  Nontechnical description/SOI

            The BUXTON component is moderately well drained; water is removed somewhat slowly during some periods. Agronomic capability

            class is 4E. Depth to bedrock is greater than 60 inches. A seasonal high water table is normally between 1.5 and 3.0 feet below the

            surface from NOV through MAY.

      Text Kind/Category:  Nontechnical description/SOI

            ROCK OUTCROP can consist of up to 90 percent exposed bedrock. Most outcrops are too hard to be broken and mixed by tillage.

      Text Kind/Category:  Nontechnical description/URB

            BUXTON has severe limitation for use as a septic tank absorbtion field because of wetness, slow percolation and slope. There is severe

             limitation for local roads and streets due to low strength, slope and frost action. For dwellings with basement, there is severe limitation

            because of wetness and slope and for small commercial buildings, there is severe limitation due to slope.

  Map Unit:  717C  -  ROCK OUTCROP-CHARLTON-HOLLIS COMPLEX, 3 TO 15 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            ROCK OUTCROP An on-site investigation is necessary to determine suitability and limitations.

      Text Kind/Category:  Nontechnical description/AGR

            The CHARLTON component is in capability subclass 6S indicating severe limitations that make the soil generally unsuited to cultivation

            and limit its use largely to pasture.

      Text Kind/Category:  Nontechnical description/AGR

            The HOLLIS component is in capability subclass 4E indicating very severe limitations that reduce the choice of plants or require very

            careful management, or both. Erosion is a limitation unless close growing plant cover is maintained.

      Text Kind/Category:  Nontechnical description/SOI

            The HOLLIS component is well drained; water is removed readily, but not rapidly. Agronomic capability class is 4E. Depth to bedrock is

            between 10 and 20 inches. The water table is normally more than 6.0 feet below the surface.

      Text Kind/Category:  Nontechnical description/SOI

            ROCK OUTCROP can consist of up to 90 percent exposed bedrock. Most outcrops are too hard to be broken and mixed by tillage.

      Text Kind/Category:  Nontechnical description/SOI

            The CHARLTON component is well drained; water is removed readily, but not rapidly. Agronomic capability class is 6S. Depth to

            bedrock is greater than 60 inches. The water table is normally more than 6.0 feet below the surface.

      Text Kind/Category:  Nontechnical description/URB

            CHARLTON has moderate limitation for use as a septic tank absorbtion field because of slope. There is moderate limitation for local

            roads and streets due to slope. For dwellings with basement, there is moderate limitation because of slope and for small commercial

            buildings, there is severe limitation due to slope.

      Text Kind/Category:  Nontechnical description/URB

            HOLLIS has severe limitation for use as a septic tank absorbtion field because of shallow depth to bedrock. There is severe limitation

            for local roads and streets due to shallow depth to bedrock. For dwellings with basement, there is severe limitation because of shallow

            depth to bedrock and for small commercial buildings, there is severe limitation due to slope and shallow depth to bedrock.

  Map Unit:  717E  -  ROCK OUTCROP-CHARLTON-HOLLIS COMPLEX, 15 TO 35 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            ROCK OUTCROP An on-site investigation is necessary to determine suitability and limitations.

      Text Kind/Category:  Nontechnical description/AGR

            The HOLLIS component is in capability subclass 6E indicating severe limitations that make the soil generally unsuited to cultivation and

            limit its use largely to pasture. Erosion is the main limitation.

      Text Kind/Category:  Nontechnical description/AGR

            The CHARLTON component is in capability subclass 6S indicating severe limitations that make the soil generally unsuited to cultivation

            and limit its use largely to pasture.

      Text Kind/Category:  Nontechnical description/SOI

            ROCK OUTCROP can consist of up to 90 percent exposed bedrock. Most outcrops are too hard to be broken and mixed by tillage.

      Text Kind/Category:  Nontechnical description/SOI

            The CHARLTON component is well drained; water is removed readily, but not rapidly. Agronomic capability class is 6S. Depth to

            bedrock is greater than 60 inches. The water table is normally more than 6.0 feet below the surface.

      Text Kind/Category:  Nontechnical description/SOI

            The HOLLIS component is well drained; water is removed readily, but not rapidly. Agronomic capability class is 6E. Depth to bedrock is

            between 10 and 20 inches. The water table is normally more than 6.0 feet below the surface.

      Text Kind/Category:  Nontechnical description/URB

            CHARLTON has severe limitation for use as a septic tank absorbtion field because of slope. There is severe limitation for local roads

            and streets due to slope. For dwellings with basement, there is severe limitation because of slope and for small commercial buildings,

            there is severe limitation due to slope.

      Text Kind/Category:  Nontechnical description/URB

            HOLLIS has severe limitation for use as a septic tank absorbtion field because of shallow depth to bedrock and slope. There is severe

            limitation for local roads and streets due to shallow depth to bedrock and slope. For dwellings with basement, there is severe limitation

            because of shallow depth to bedrock and slope and for small commercial buildings, there is severe limitation due to slope and shallow

            depth to bedrock.

  Map Unit:  718A  -  SACO VARIANT SILT LOAM, 0 TO 3 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            The map unit is in capability subclass 6W indicating severe limitations that make the soil generally unsuited to cultivation and limit its

            use largely to pasture. Water in or on the soil interferes with plant growth or cultivation.

      Text Kind/Category:  Nontechnical description/SOI

            The map unit is very poorly drained; water is removed from the soil so slowly that free water remains near the surface. Agronomic

            capability class is 6W. Depth to bedrock is greater than 60 inches. A seasonal high water table is normally between 0 and 1.0 feet below

             the surface from NOV through JUN.

      Text Kind/Category:  Nontechnical description/URB

            This map unit has severe limitation for use as a septic tank absorbtion field because of flooding, wetness and poor filtration. There is

            severe limitation for local roads and streets due to wetness, flooding and frost action. For dwellings with basement, there is severe

            limitation because of flooding and wetness and for small commercial buildings, there is severe limitation due to flooding and wetness.

  Map Unit:  719B  -  SUFFIELD SILT LOAM, 3 TO 8 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            The map unit is in capability subclass 2E indicating limitations that reduce the choice of plants or require moderate conservation

            practices. Erosion is a limitation unless close growing plant cover is maintained.

      Text Kind/Category:  Nontechnical description/SOI

            The map unit is well drained; water is removed readily, but not rapidly. Agronomic capability class is 2E. Depth to bedrock is greater than

             60 inches. The water table is normally more than 6.0 feet below the surface.

      Text Kind/Category:  Nontechnical description/URB

            This map unit has severe limitation for use as a septic tank absorbtion field because of slow percolation. There is severe limitation for

            local roads and streets due to frost action and low strength. For dwellings with basement, there is moderate limitation because of shrink-

            swell and for small commercial buildings, there is moderate limitation due to shrink-swell.

  Map Unit:  719C  -  SUFFIELD SILT LOAM, 8 TO 15 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            The map unit is in capability subclass 3E indicating severe limitations that reduce the choice of plants or require special conservation

            practices, or both. Erosion is a limitation unless close growing plant cover is maintained.

      Text Kind/Category:  Nontechnical description/SOI

            The map unit is well drained; water is removed readily, but not rapidly. Agronomic capability class is 3E. Depth to bedrock is greater than

             60 inches. The water table is normally more than 6.0 feet below the surface.

      Text Kind/Category:  Nontechnical description/URB

            This map unit has severe limitation for use as a septic tank absorbtion field because of slow percolation. There is severe limitation for

            local roads and streets due to frost action and low strength. For dwellings with basement, there is moderate limitation because of slope

            and shrink-swell and for small commercial buildings, there is severe limitation due to slope.

  Map Unit:  720A  -  WHATELY VARIANT FINE SANDY LOAM, 0 TO 3 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            The map unit is in capability subclass 6W indicating severe limitations that make the soil generally unsuited to cultivation and limit its

            use largely to pasture. Water in or on the soil interferes with plant growth or cultivation.

      Text Kind/Category:  Nontechnical description/SOI

            The map unit is very poorly drained; water is removed from the soil so slowly that free water remains near the surface. Agronomic

            capability class is 6W. Depth to bedrock is greater than 60 inches. A seasonal high water table is normally between 0 and 1.0 feet below

             the surface from NOV through JUN.

      Text Kind/Category:  Nontechnical description/URB

            This map unit has severe limitation for use as a septic tank absorbtion field because of wetness and slow percolation. There is severe

            limitation for local roads and streets due to wetness and frost action. For dwellings with basement, there is severe limitation because of

            wetness and for small commercial buildings, there is severe limitation due to wetness.

  Map Unit:  721C  -  WINDSOR-ROCK OUTCROP COMPLEX, 3 TO 15 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            ROCK OUTCROP An on-site investigation is necessary to determine suitability and limitations.

      Text Kind/Category:  Nontechnical description/AGR

            The WINDSOR component is in capability subclass 4S indicating very severe limitations that reduce the choice of plants or require very

            careful management, or both. Droughtiness is a limitation.

      Text Kind/Category:  Nontechnical description/SOI

            The WINDSOR component is excessively drained; water is removed very rapidly. Agronomic capability class is 4S. Depth to bedrock is

            greater than 60 inches. The water table is normally more than 6.0 feet below the surface.

      Text Kind/Category:  Nontechnical description/SOI

            ROCK OUTCROP can consist of up to 90 percent exposed bedrock. Most outcrops are too hard to be broken and mixed by tillage.

      Text Kind/Category:  Nontechnical description/URB

            WINDSOR has severe limitation for use as a septic tank absorbtion field because of poor filtration. There is moderate limitation for local

             roads and streets due to slope. For dwellings with basement, there is moderate limitation because of slope and for small commercial

            buildings, there is severe limitation due to slope.

  Map Unit:  721D  -  WINDSOR-ROCK OUTCROP COMPLEX, 15 TO 25 PERCENT SLOPES

      Text Kind/Category:  Nontechnical description/AGR

            ROCK OUTCROP An on-site investigation is necessary to determine suitability and limitations.

      Text Kind/Category:  Nontechnical description/AGR

            The WINDSOR component is in capability subclass 6S indicating severe limitations that make the soil generally unsuited to cultivation

            and limit its use largely to pasture. Droughtiness is a significant limitation.

      Text Kind/Category:  Nontechnical description/SOI

            The WINDSOR component is excessively drained; water is removed very rapidly. Agronomic capability class is 6S. Depth to bedrock is

            greater than 60 inches. The water table is normally more than 6.0 feet below the surface.

      Text Kind/Category:  Nontechnical description/SOI

            ROCK OUTCROP can consist of up to 90 percent exposed bedrock. Most outcrops are too hard to be broken and mixed by tillage.

      Text Kind/Category:  Nontechnical description/URB

            WINDSOR has severe limitation for use as a septic tank absorbtion field because of poor filtration and slope. There is severe limitation

            for local roads and streets due to slope. For dwellings with basement, there is severe limitation because of slope and for small

            commercial buildings, there is severe limitation due to slope.